¡¤BK-6A Bridge Load Cell
|
Performance specification
|
|
Rated Capacity
|
BK-6A
|
0¡«10,20 |
t |
|
Rated output
|
1.5¡«2.0 |
mV/V |
|
Linearity
|
¡À0.05; ¡À0.1 |
%F.S |
|
Hysteresis
|
¡À0.05; ¡À0.1 |
%F.S |
|
Repeatability
|
¡À0.05; ¡À0.1 |
%F.S |
|
Operating Temperature Range
|
-10¡«+60 |
¡æ |
|
Compensated Temperature
|
room temperature ¡«+60 |
¡æ |
|
Temperature Effect On Zero
|
¡À0.05 |
%F.S/10 ¡æ |
|
Temperature Effect On Output
|
¡À0.05 |
%F.S/10 ¡æ |
|
Excitation
|
12 |
VDC |
|
Insulation Resistance
|
2000 |
M¦¸/100VDC |
|
Input Resistance:Steel
|
760¡À5 |
¦¸ |
|
Aluminum
|
790¡À5 |
¦¸ |
|
Output Resistance
|
700¡À5 |
¦¸ |
|
Zero Output
|
0¡«¡À1 |
%F.S |
|
Overload Capacity
|
120 |
%F.S |
|
Electrical Connection
|
|
Leads designation
|
Socket
|
Color
|
| Power + |
1
|
Red
|
| Signal + |
2
|
Yellow
|
| Signal - |
3
|
White
|
| Power - |
4
|
Blue
|
| Ground |
/ |
Black |
|